NSPECTION AND SERVICE BEFORE EACH OPERATION
C
LEANING OF AIR CLEANER
When the element is very dirty or when the oil has been
used up making the element dry, after cleaning the
element soak it in kerosene and strongly wring out the
element with one hand.
Use of heat or flame is absolutely prohibited.
Cleaning and service at respective sections
Clean at around the muffler.
Clean the cooling fins and the cooling air inlet.
Inspect and retighten bolts and nuts.
Inspect the fuel leakage.
I
NSPECTION AND SERVICE AT EVERY
S
PARK PLUG SERVICE
Recommended spark plug: E6TC
1. Disconnect the spark plug cap, and remove any dirt from around the spark plug area.
2. Remove the spark plug with a spark plug wrench.
3. Inspect the spark plug. Replace it if the electrodes are worn, or if the insulator is cracked or
chipped.
4. Measure the spark plug electrode gap with a suitable gauge. The gap should be
0.028~0.031 in (0.70~0.80mm). Correct the gap if necessary, by carefully bending the side
electrode.
5. Install the spark plug carefully, by hand, to avoid cross-threading.
6. After the spark plug seats, tighten with a spark plug wrench to compress the sealing
washer.