Programmable function settings
LED DISPLAY
DEFINITION
1
Options of gate
Opening direction
2
Automatic closing
3
There actions of the
photocells / safety
edge /loop detector
when they detecting
obstacles
4
Motor speed
(% full speed)
5
The deceleration
point (% full distance)
Deceleration
6
Speed (% full
speed)
7
Over current
setting
FUNCTION
VALUE
Clockwise Opening
1-0
1-1
Counterclockwise Opening
2-0
No automatic closing
2-1
5 seconds
2-2
15 seconds
2-3
30 seconds
2-4
45 seconds
2-5
60 seconds
2-6
80 seconds
2-7
120 seconds
2-8
180 seconds
3-1
Please the function setting
after 8
3-2
3-3
4-1
50% Learning Speed
4-2
70% Learning Speed
4-3
85% Learning Speed
4-4
100% Learning Speed
5-1
75% of full distance
5-2
80%
5-3
85%
5-4
90%
5-5
95%
6-1
80%
6-2
60%
6-3
40%
6-4
25%
6-5
10%
7-1
2A
7-2
3A
7-3
4A
7-4
5A
7-5
6A
7-6
7A
DESCRIPTION
The function can adjust the direction of gate
opening.
The factory setting is "1-1".
1. This function can cause the gate to
close
2. automatically after the paused time.
The factory setting is "2-2".
1. Please do the function setting after H & J
2. The factory setting is "3-1".
1.The function can adjust the running
speed of motor.
2.The factory setting is "4-4".
1. The factory setting is "5-1".
1. The factory setting is "6-4"
1. The function can adjust the running
force of motor
to be compatible with the gate weight.
2. The factory setting is "7-6".
Opening your life
1 10

Publicidad