Descargar Imprimir esta página

Accessmatic Infinity 624 Manual De Usuario página 38

Publicidad

Idiomas disponibles

Idiomas disponibles

Infinity
624
Testing and checking
• Make sure the notices included in Warnings has been carefully observed.
• Release the gearmotor with the proper release key.
• Make sure the gate can be moved manually during opening and closing phases with a force of max. 390N (40 kg approx.)
• Lock the gearmotor.
• Using the Key selector switch, push button device or the radio transmitter, test the opening, closing and stopping of the gate and
make sure that the gate is in the intended direction.
• Check the devices one by one (photocells, ashing light, key selector, etc.) and con rm the control unit recognizes each device.
Recognition of LED
LED Indication
LED1 Photocells
LED2 Photocells
Technical feature
Model
power cord
Power supply
cicle / hour
velocidad apertura cerrado
ciclo de trabajo
Maximum gate weight
Work temperature
Maximum number of controls
Frequency
Descriptions
LED1 will be on when the rst pair of the photocells are activated
LED2 will be on when the second pair of the photocells are activated
INFINITY624
110V - 60 Hz
24V
30
14mt/min
80%
600Kg
-20°C until 50°C
50
433 Mhz
Opening your life
1 13

Publicidad

loading