MAINTENANCE / RECOMMENDATIONS
1 - Air filter maintenance :
• It is necessary to periodically purge the air filter. In order to do so, loosen the grey tap located under the tank and press it to start the purge. Tighten
the tap when finished.
• Disassembly :
- Unplug the air supply.
- Unscrew the tank.
- Pull the cube downwards and then put it down.
- The filtering part is white, clean or replace if necessary.
2 - Periodical maintenance:
• Periodically remove the cover and dust with an air gun. You are advised to have the electrical connections checked by a qualified person, with an
insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, an after sales
service or a qualified person to prevent danger.
• Do not obstruct the machine's air intake, to allow air circulation.
• Check that the torch does not have any cracks or exposed wires.
• Check that the consumables are installed properly and not worn.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the cutting equipment. During set up, the operator must
ensure that the machine is unplugged. Connecting generators in a series or a parallel circuit is forbidden. It is recommended to use the welding
cables supplied with the unit in order to obtain the optimum product settings.
MACHINE SUPPLIED WITH
The accessories supplies with the machine are to be used only with the same models.
HARDWARE DESCRIPTION (FIG-1)
1-
Control board
2-
Earth cable connector
3-
Torch connector
4-
Manometer
CONTROL BOARD (IHM) (FIG-2)
1-
Power indicator (green)
2-
Thermal protection and over current protection indicator
POWER SUPPLY – STARTING UP
EASYCUT 30 FV is supplied with a 16 A plug, type CEE7/7. Such 16A is suffcient for most of applications. However, for an optimal use of this cutting
machine, it can be necessary to replace this 16 A plug by a 25 A model.
They are power supplied by a 230V +/- 15% (50 - 60 Hz) EARTHED installation and are protected to work with generators. This hardware must only
be used with a one phase electricity supply protected by a earthing wire.
The absorbed effective current (I1eff) is displayed on the machine, for optimal use. Check that the power supply and its protection (fuse and/or circuit
breaker) are compatible with the current needed by the machine.
14
Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance work. DANGER High
Voltage and Currents inside the machine.
Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
4 m
2 m - 10 mm²
Starting kit
Pneumatic fittings
EASYCUT 30 FV
EASYCUT 30 FV
Ref. 013858
8 mm + 10 mm
Air regulator (air pressure adjustment)
5-
6-
Compressed air connector
7-
Air filter
8-
Power supply cable
3-
Current setting
EN

Publicidad

loading