Install Monitored Entrapment Protection Device
This operator contains an inherent (internal) entrapment protection
system and REQUIRES the addition of a LiftMaster external
monitored entrapment protection system (non-contact photoelectric
sensor or contact edge sensor) for EACH entrapment zone prior to
gate movement. System includes six monitored entrapment
protection inputs to cover all entrapment zones. Refer to the manual
for complete information.
Photoelectric Sensor
Reflector
CONTROL BOARD
BIPART
DELAY
4
2
6
8
OPEN
OPEN
LEFT
RIGHT
HANDING
PROGRAM REMOTE CONTROL
ANTENNA
CURRENT
MOTOR DRIVE
RPM & LIMITS ALARM EXP.
24 VAC IN
SENSOR
ID RESET
BOARD
1. Press and release the LEARN button on
the control board (operator will beep
and green XMITTER LED will light).
2. Press the remote control button.
The operator will time out of programming
mode after 30 seconds.
WIRING AND ADJUSTMENTS
Connect Power and Earth Ground Rod
Junction Box
1. Turn off the AC power from the main
power source circuit breaker.
2. Run AC power wires to the operator.
3. Connect the green wire to the earth
ground rod and AC ground using a wire
nut.
4. Connect the white wire to NEUTRAL.
5. Connect the black wire to HOT.
6. Turn on the AC power from the main
power source circuit breaker.
INCOMING
POWER
EARTH GROUND ROD
Install the earth ground
rod within 3 feet (.9 m)
Check national
of the operator.
and local codes
for proper depth
Set the Limits and Force
SET THE HANDING
OPEN
OPEN
LEFT
RIGHT
1. To set the initial handing of
the operator, make sure that
HANDING
both OPEN LEFT and OPEN
RIGHT LEDs are flashing. If
they are not flashing, press
and hold both the OPEN
BIPART
DELAY
4
LEFT and OPEN RIGHT
6
2
OPEN
OPEN
8
LEFT
RIGHT
handing buttons until both
HANDING
handing LEDs start to flash
and the operator beeps.
2. Press and release either the
OPEN RIGHT or OPEN LEFT
ANTENNA
CURRENT
MOTOR DRIVE
RPM & LIMITS ALARM EXP.
24 VAC IN
SENSOR
ID RESET
BOARD
button depending on which
direction the gate should
open. The corresponding
handing LED will turn solid.
SET THE LIMITS
1. Make sure the gate is closed.
2. Press and release the OPEN test
button to open the gate.
3. Press the STOP test button when the
desired OPEN limit is reached. Adjust
the limit nut or cam so it makes
contact with the OPEN limit switch at
this position. If the gate stops early,
move the limit nut or cam to allow for
additional travel.
4. Press and release the CLOSE test
button to close the gate.
5. Press the STOP test button when the
desired CLOSE limit is reached.
Adjust the limit nut or cam so it
makes contact with the CLOSE limit
switch at this position. If the gates
stops early, move the limit nut to
allow for additional travel.
SET THE FORCE AND RUN
DISTANCE
1. Press the OPEN test
button to open the gate.
2. Press and release both the
OPEN LEFT and OPEN
OPEN
OPEN
LEFT
RIGHT
RIGHT handing buttons.
HANDING
3. Press the handing button
below the solid LED.
4. Run the operator one full
cycle using the test
BIPART
DELAY
4
buttons. The initial forces
2
6
OPEN
OPEN
8
LEFT
RIGHT
HANDING
and run distance will be
set during this cycle.
ANTENNA
CURRENT
MOTOR DRIVE
ID RESET
RPM & LIMITS ALARM EXP.
24 VAC IN
SENSOR
BOARD
Perform the Obstruction Test
1. Open and close the gate with the test buttons, ensuring that the
gate is stopping at the proper open and close limit positions.
2. Place a solid object between the open gate and a rigid structure.
Ensure that the gate, the solid object, and the rigid structure can
withstand the forces generated during this obstruction test.
3. Run the gate in the close direction. The gate should stop and
reverse upon contact with the solid object. If the gate does not
reverse off the solid object, reduce the force setting by turning
the force control slightly
counter-clockwise. The
gate should have enough
force to reach both the
open and close limits, but
MUST reverse after
contact with a solid
object.
4. Repeat the test for the
open direction.
Installation Checklist
Check the following before leaving the site:
Are all the wiring and connections tightly connected?
Is the pin removed from the vent plug on the gear box?
Is the AC power on?
Make sure the antenna is in place when using wireless dual gates or
on-board transmitters. Operator will be intermittent at times without it.
Remove the protective anti-scratch film from the photoelectric sensors.
Leaving the film on can result in poor sensitivity as the film
decays/yellows/peels.
Confirm whether the site should be fail safe or secure and set the
operator accordingly.
Confirm operation of the following (if applicable):
Entrapment protection devices
Loops
TES relay
SOS/emergency transponders
Check operation of ALL legacy receivers using the MAX transmitter
Timer-to-Close setting
Quick close setting
Anti-tailgate setting