Installation
Installation
Installation requirements
Air quality
• For optimum performance and maximum product life we recommend the
use of compressed air with a maximum dew point of +10°C (50°F). We also
recommend to install an Atlas Copco refrigeration type air dryer.
• Use a separate air filter which removes solid particles larger than 30 mi-
crons and more than 90% of liquid water. Install the filter as close as possi-
ble to the product and prior to any other air preparation units to avoid pres-
sure drop.
Make sure that the hose and couplings are clean and free from dust before
connecting to the tool.
Both lubricated and lubrication free products will benefit from a small
quantity of oil supplied from a lubricator.
Air lubrication guide
Brand
Atlas Copco
Q8
Shell
Compressed air connection
WARNING Compressed air can cause serious injury
Always shut off the air supply, drain hose of air pressure and disconnect
►
the tool from air supply; when not in use, before making any adjustments
to the product - for example changing accessories, or when making re-
pairs.
WARNING Whipping hoses can cause serious injury
Always make sure that there are no damaged or loose hoses or fittings.
►
WARNING Compressed Air
High air pressure can cause severe damage and bodily injury.
Do not exceed maximum air pressure.
►
Make sure that there are no damaged or loose hoses or fittings.
►
For correct air pressure and hose size, see section Technical data.
Make sure that the hose and couplings are clean and free from dust before
connecting to the tool.
Load chain
NOTICE Lubricate the Chain Before Use
The hoist must not be used without lubricating the chain. The load chain must
be lubricated before use since the chain is not properly lubricated for use upon
delivery. Failure to lubricate will lead to greatly reduced lifetime of the chain.
Lubricate the chain before use.
►
10
EN
Air lubrication
Optimizer (1 liter) 9090 0000 04
Chopin 46
Shell Air Tool Oil S2 A 320
© Atlas Copco Industrial Technique AB - 9836 9833 00
LLA250 ATEX