Descargar Imprimir esta página

Everbilt SBA025BC Guía De Uso Y Mantenimiento página 22

Ocultar thumbs Ver también para SBA025BC:

Publicidad

Quick Start Guide
Sump Pump
(Pump pictured is typical)
YOU WILL NEED:
Tools:
Screw Driver
Hacksaw
Channel Locks
Pipe wrench
Tape Measure
Cable Ties
3. Inserting The Pump
Place the pump in the sump; make sure that nothing
interferes with switch operation (tether switch shown).
Materials:
Threaded Adapter
1-1/4'' or 1-1/2''
(Pipe to Pump)
ABS or PVC Pipe
PVC
1-1/4'' or 1-1/2''
ABS or PVC Cement
Check Valve
(to match the pipe)
Unless otherwise noted, models with a tethered float
switch require a sump pit at least 14'' in diameter.
Models with a vertical float switch require a sump pit at
least 10'' in diameter.
4. Completing The Plumbing
Finish installing the necessary plumbing. Follow the
glue manufacturer's instructions for curing time.
Plugging In The Pump
Plug the pump into a 15-amp circuit (20A for 1/2 HP).
The circuit should be GFCI protected and dedicated to
the sump pump.
Read your manual for installation, operation, and safety information.
This guide neither supplements nor replaces the Owner's Manual.
1. Sump Requirements
The pit must be covered. It is usually 10-18'' in diameter
and 14-18'' deep. See pump owner's manual for pit size
needed. Install on a hard surface: brick, cement, or
concrete block; no sand, clay, or gravel.
10-18'' diameter
14-18''
Sump Pit
depth
5. Verifying Operation
Check the pump's operation by filling the sump with
water until the pump starts. Let it run until it has
pumped down the sump and stopped. Replace the sump
cover.
2. Installing The Discharge Plumbing
Install the discharge plumbing and check valve on the pump:
A. Use Teflon tape-NOT pipe joint compound.
B. Tighten the pipe into the pump.
C. Install the check valve as close to the pump as
possible.
D. Drill an anti-airlock hole as shown. The hole must be
in the sump.
1-1/4" or 1-1/2"
Discharge Pipe
Check Valve
Anti-airlock Hole
PVC Threaded Adaptor
WARNING:
WARNING: Plastic pipe glue is extremely flammable.
Follow the glue manufacturer's instructions carefully if
you are using glued plastic pipe for the discharge pipe.
Install in compliance with all applicable laws, codes,
and ordinances. Non-compliance may cause product
failure, property damage, and/or personal injury.
The pump should start and stop at the water levels
shown below. See your pump owner's manual to
determine the pumping range for your pump.
Tethered switch models will be several inches
underwater before the pump starts.
Do not use an extension cord with a sump pump.
Regularly inspect pump inlet and clean away any
debris.
Switch Setting in Inches (mm)
ON
OFF
Tethered Switch
13.5"-14.5''(343-368)
5.5"-6.5''(139-16.5)
Vertical Switch
8"-9"(203-228)
3.5"-4.5"(89-114)

Publicidad