Servicing
Servicing of Honeywell Miller SRL must
only be carried out by Honeywell Safety
Products or persons or entities authorized
in writing by Honeywell. A record log of
all servicing and inspection dates for
this device must be maintained. Only
original Honeywell replacement parts
are approved for use in this device.
Contact your Honeywell distributor or call
Honeywell Technical Service at 800-873-
5242 for a return authorization number.
Honeywell Miller Self-Retracting Lifelines
(included in this manual) require no annual
factory recertification for Honeywell Miller.
ANSI Z359.14-2021 and CSA Z259.2.2
standards are voluntary; and ultimately,
the end-user/company must elect to
follow the inspection and recertification
requirements if it is to be compliant with
the standard.
TABLE 3: ANSI Z359.14-2021 and CSA Z259.2.2: Inspection Requirements
Application
Type of Use
Examples
Infrequent
Rescue & con-
to Light
fined space,
Factory
maintenance
Moderate to
Transportation,
Heavy
Residential
construc-
tion, Utilities,
Warehouse
Severe to
Commercial
Continuous
construction,
Oil & Gas,
Mining
1) Failure of a worker to perform "before each use" inspection or failure of an inspection by a worker shall initiate the requirement for inspection by a
competent person.
2) Failure of a competent person to perform inspections as specified in this Table, or failure of an inspection by the competent person shall initiate product
revalidation or disposal.
3) Determination of the type of use category shall be determined by a competent person.
4) A SRL that is considered non-repairable, or not designed for disassembly such that internal inspection is not possible without rendering it unserviceable, is
not subject to revalidation inspection. These SRL's shall have service life and other inspection requirements as provided by the manufacturer's instructions.
Conditions of Use
Good storage conditions,
indoor or infrequent outdoor
use, room temperature,
clean environments
Fair storage conditions, in-
door and extended outdoor
use, all temperatures, clean
or dusty environments
Harsh storage conditions,
prolonged or continuous
outdoor use, all tempera-
tures, dirty environment
15
Note for CSA Approved Products:
Z259.2.2 requires Type 2 and Type 3 devices
to be returned to the manufacturer or an
approved service agent no more than 2 years
after the date of manufacturer for inspection
and maintenance and annually thereafter.
Cleaning and Storage
This device must be kept clean and free
of contaminants. Periodically clean the
exterior of the device and wipe the lifeline
using a damp cloth and mild detergent.
When not in use, equipment shall be
stored in a manner as to preclude
damage from environmental factors,
such as temperature, light, UV, excessive
moisture, oil, chemicals and their vapors,
or other degrading elements. The lifeline
should be fully retracted into the device
when not in use.
Competent
Worker
Person
Inspection
Inspection
Frequency
Frequency
Before each
Annually
use
Before each
Semi-annually
use
to annually
Before each
Quarterly to
use
semi-annually
CSA
APPLIES TO CSA
ONLY Product
Revalidation
Frequency
At least every
5 years but not
more than inter-
vals required by
the manufacturer
At least every
2 years but not
more than inter-
vals required by
the manufacturer
At least annually
but not more than
intervals required
by the manufac-
turer