5 - Installation instructions
EN
Installation
These instructions are aimed at qualified fitters as a guide to
installation, adjustment and maintenance in compliance with the
laws and standards in force. The operations must always be carried
out with the appliance disconnected from the electricity supply.
This appliance is not provided with a combustion product discharge.
It is recommended that it be installed insufficiently aerated places, in
terms of the laws in force. The quantity of air which is necessary for
combustion must not be below 2.0 m3/h for each kW of installed
power. See table of burner power.
Positioning (Fig. 9-10)
The appliance is made to be fitted into a counter top, as show in the
figure. Apply the sealant supplied around the whole perimeter of
the hob. Installation over an oven is not recommended, but if this is
necessary, check that:
• the oven has an efficient cooling system;
• there is no passage of hot air from the oven to the hob;
• allow air passages as shown in the figure.
520
880
12
Fig. 9
900
55
490
Fig. 10
Gas connection (Fig. 11)
Connect the appliance to the gas cylinder or to the installation
according to the prescribed standards in force, and ensure
beforehand, that the appliance matches the type of gas available.
Other wise, see "Adaptation to various types of gas". Further more,
check that the feed pressure fall swithin the values described on the
table: "User chacteristics".
Fig. 11
Rigid/semi rigid metalconnection
Carry out the connection with fittings and metal pipes (even flexible
pipes) so as to obtain counter stress the inner parts of the appliance.
N.B. - when the installation has been carried out, check the perfect
sealing of the entire connection system, by using a soapy solution.