CONTROL MODES MENU
0-10VDC
page 2 of 3
To program the pump for 0-10VDC control mode, set the response curve in Program Settings, return
to the 0-10VDC Control menu and program the desired options under Alarm Settings, then exit to
the Main Menu via the Go To Main Menu option.
NAVIGATION
Moves up in a menu, toggles
between options, or increase a value
Holding the
or
button causes the numbers to change rapidly.
Control Mode
- Manual
- 4-20mA
- 0-10VDC
Continued on next page
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Moves down in a menu, toggles
between options, or decreases a value
0-10 VDC
- Program Settings
- Alarm Settings
- Go to Main Menu
0-10 VDC
- Program Settings
- Alarm Settings
- Go to Main Menu
0-10 VDC
- Program Settings
- Alarm Settings
- Go to Main Menu
To Main Menu
Moves one step back in
a menu, when permitted
Set the response curve by entering the
Minimum Signal
Minimum Signal, the % pump speed at
_ 0.0 VDC
Minimum Signal, and the % pump
adjust
set
speed at Maximum Signal.
Speed at Min VDC
_ _ 0%
adjust
set
Maximum Signal
10.0 VDC
adjust
set
Speed at Max VDC
100 %
adjust
set
To 0-10 VDC menu
36
Sets a value in a menu
When ENTER is pressed for the final
digit, the display will return to the
0-10VDC menu.