CONTROL MODES MENU
HALL EFFECT
page 2 of 3
The menu example illustrates Units in gallons. For liters, select Liters in the Configuration menu. When in Control
mode, liters are represented by P/L on the display.
NAVIGATION
Moves up in a menu, toggles
between options, or increase a value
Holding the
or
button causes the numbers to change rapidly.
To enter the Hall Effect sub-menu,
highlight "Hall Effect" in the Control
Mode menu and press ENTER.
Control Mode
- 0-10VDC
- Pulse
- Hall Effect
Continued on next page
After completing the Program
Settings, select "Alarm
Settings" and press ENTER to
go to the Alarm
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Moves down in a menu, toggles
between options, or decreases a value
Hall Effect
- Program Settings
- Alarm Settings
- Go to Main Menu
Hall Effect
- Program Settings
- Alarm Settings
- Go to Main Menu
Hall Effect
- Program Settings
- Alarm Settings
- Go to Main Menu
To Main Menu
After completing Program
Settings and Alarm Settings,
select "Go To Main Menu" and
press ENTER to return to the
Main Menu.
After the settings are entered, the display
41
Moves one step back in
a menu, when permitted
Meter K Factor
P/G
1000.0000
adjust
set
Minimum Process Flow
_ _ 0.0 GPM
adjust
set
Speed @ Min Flow
_ _ 0 %
adjust
set
Maximum Process Flow
000.0 GPM
adjust
set
Speed @ Max Flow
100 %
adjust
set
To Hall Effect menu
returns to Hall Effect menu and
Alarm Settings can be programmed.
Sets a value in a menu
Set the meter K factor.
Set the minimum process flow rate
at which the pump is to activate.
Set the percent pump speed for the
minimum process flow rate.
Set the maximum process flow rate.
Set the percent pump speed for
the maximum process flow rate.