Descargar Imprimir esta página

Trotec IRD 1200 Manual De Instrucciones página 134

Ocultar thumbs Ver también para IRD 1200:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Assembly
Warning of electrical voltage
Risk of injury due to incorrect assembly!
Local or national regulations may apply for installation..
We recommend to have the installation carried out by a
qualified electrician.
The device is suited for wall and ceiling mounting. Observe the
following requirements for the installation:
Warning
Risk of fire due to improper installation!
There is a risk of fire if the required minimum
distances are not observed.
Observe the "Installation" section in the "Assembly and
start-up" chapter and the technical data in the
"Technical annex" chapter.
Mounting the wall/ceiling holder
Info
The mounting procedure is identical for all devices.
ü Use tools suitable for the intended task.
1. Connect one device holder and one mounting bracket each
using two medium hexagon screws (M6), hexagon
nuts (M6) and spring washers (Ø 6.1 mm).
2. Connect the second device holder to the second mounting
bracket.
EN
3. Push the two device holders into the guide rails one after
the other. Pay attention not to push the device holders
over the power cable when inserting them in the guide rail.
4. The brackets' position can be freely adjusted. The
recommended distances are provided in the table below:
Holder
distance
Minimum
Maximum
5. Tighten the two wing screws on the device to lock the
device holders.
infrared radiant heater IRD 1200 / IRD 1800 / IRD 2400 / IRD 3200
IRD 1200
IRD 1800
IRD 2400
400 mm
600 mm
800 mm
930 mm
1195 mm
1460 mm
IRD 3200
1100 mm
1815 mm
7

Publicidad

loading

Este manual también es adecuado para:

Ird 1800Ird 2400Ird 3200