Descargar Imprimir esta página

Trotec IRD 1200 Manual De Instrucciones página 137

Ocultar thumbs Ver también para IRD 1200:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
8. Connect the mounting brackets on the device to those on
the wall / ceiling at the desired inclination angle. For each
side, use two Phillips screws, two small hexagon nuts (M4)
and spring washers (Ø 4.1 mm).
9. Make sure that the device is attached securely.
Effective range
Info
Note that in outdoor areas, the effective range is
influenced by the weather and may be reduced.
The device heats objects and persons inside a certain effective
range.
c
a
Height
c
Width
10
a
d
b
b
Depth
d
Effective range
infrared radiant heater IRD 1200 / IRD 1800 / IRD 2400 / IRD 3200
IRD 1200
IRD 1800
a
2.2 m
2.2 m
b
2.1 m
2.1 m
c
1.55 m
1.95 m
d
approx.
approx.
2
3.3 m
4.1 m
Start-up
Info
Odours might arise upon initial start-up or after a
longer period of non-use.
• Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
• Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
• Make sure that extension cables are completely unrolled.
• Make sure that there are no curtains or similar objects in
the immediate vicinity.
Prior to initial start-up, insert batteries in the remote control.
Connecting the power cable
• Insert the mains plug into a properly fused mains socket.
• Make sure that the power cable is guided along the back
of the device. Never guide the power cable along the front
of the device!
IRD 2400
IRD 3200
2.2 m
2.2 m
2.1 m
2.1 m
2.35 m
2.75 m
approx.
approx.
2
2
2
5.0 m
5.8 m
EN

Publicidad

loading

Este manual también es adecuado para:

Ird 1800Ird 2400Ird 3200