in six month intervals in order to guarantee perfect air circulation.
Procedure:
Step 1: Unscrew the fixation screws of the housing cover.
Step 2: Remove the housing cover.
Step 3: Remove the dust protection filters and clean them.
Step 4: Replace the dust protection filters in the housing and tighten the fixation screws.
Step 5: Replace the housing cover and tighten the fixation screws.
The interior of the fixture should be cleaned at least annually using a vacuum-cleaner or an air-jet.
The dichroic colour-filters and the internal lenses should be cleaned monthly.
To ensure a proper function of the rotating parts, we recommend lubrication in six-month intervals. The
quantity of oil must not be excessive in order to avoid that oil runs out during the rotation.
There are no serviceable parts inside the device except for the lamp and the fuse. Maintenance and service
operations are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamp".
Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
Do not operate this device with opened cover!