b) Mounting the Device
Remark : Please consider the contents of EN 60598-2-17 and your own national norms during
installation. A qualified technician should carry out the installation!
• The supporting structure for the device must be able to carry 10 times the required weight for
one hour without deformation of that structure.
• The installation must always be secured by a secondary safety attachment e.g. a safety
cable.
• Do not stand directly below the device when mounting, removing or servicing it. Have a
qualified technician check the installation once a year and once before you bring the device
into service.
• Install the device in a location with few passers-by that is inaccessible to unauthorised
persons.
• Overhead mounting requires extensive experience : calculating work load limits, determining
the installation material to be used... Have the material and the device itself checked
regularly. Do not attempt to install the device yourself if you lack these qualifications as
improper installation may result in injuries.
• Make sure there is no flammable material within a 50cm radius of the device.
• A qualified electrician should carry out the electric connection.
• Connect the device to the mains with the power plug. In general, lighting effects should not
be connected to dimming packs. Put the power switch in the ON position. The device will
produce colourful light beams at a steady pace.
• The installation has to be approved by an expert before the device is taken into service.
5. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, mounting supports and connections should not be modified or tampered with
e.g. do not drill extra holes in mounting supports, do not change the location of the
connections, ...
3. The electric power supply cables should be undamaged. Have this device installed by a
qualified technician.
4. Mechanically moving parts must not show any signs of wear and tear.
6. Caution
• Disconnect the device from the mains prior to maintenance.
• Use a moist cloth to clean the device and avoid the use of alcohol or solvents for cleaning
purposes.
• This device does not contain any user-serviceable parts with the exception of the lamps.
Refer to "a) Installing or Replacing a Lamp" under "4. Installation" for further details.
• Spare parts should be ordered with your local dealer.