Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower may only be used for bathing, hygiene
and body cleaning purposes.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!
Technical Data
Operating pressure:
Recommended operating pressure:
Fault
Head shower extremely leaky
4
English
max. 1 MPa
0,15 - 0,4 MPa
Cause
- Head shower soiled / scaled
Assembly (see page 33)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 35)
i
Installation example (see page 36)
Flow diagram (see page 36)
Spare parts (see page 46)
Cleaning (see page 42)
Remedy
- Clean / descale head shower
(see page 42)
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min