Connect the locally approved flexible fuel supply line (not included) to the LPG/NG connector (inlet)
on the control panel and the fuel Source. We recommend you use FIRMAN 25ft (7.62m) Quick Connect
Hose Kit (Model 1815) or 10ft (3m) Quick Connect Hose Kit (Model 1805) for Natural Gas (NG)
connection (This item is not included). Hose requirements may vary in different regions depending
on local codes. Contact your local licensed plumber to ensure complete compliance with all codes.
Make sure the NG source location and hose used allows the portable generator to be located at least
20 ft (6 m) from any occupied spaces.
Indicator light - Battery Power Saving Mode
This generator is equipped with an electronic module which consumes battery power. When the
main fuel selector switch is turned to the GAS or LPG/NG position, the indicator light will turn
RED for up to 4 minutes (before going off). Starting the engine successfully anytime during the 4
minutes will turn the indicator light GREEN. If portable generator is not started during this
4-minute period the portable generator will switch to Battery Power Saving Mode to conserve
battery life.
NOTICE Your portable generator is equipped with an internal battery charger that will properly
charge the battery only when the engine is running.
The generator cannot be started in Battery Power Saving Mode. Turn main fuel selector switch to
the off position and back to the GAS or LPG/NG position to reset the RED indicator 4-minute
electronic module.
3.Starting the Generator on Gasoline
1. Before starting the generator, check for loose or missing parts and for any damage which may
have occurred during shipment. Ensure spark plug, muffler, fuel cap, and air cleaner are all in place.
2. Move portable generator outdoors to safe operating location at least 20feet (6m) from any
occupied spaces.
3.If connected make sure the LPG cylinder knob or the NG source valve are fully closed or
disconnected.
English
NG Shut Off Valve
CLOSE
16
OPERATION
Customer Service: 1-844-FIRMAN1