STEP 4. INSTALLING THE CONDUIT
Remove the conduit connection plate and rotate it as shown below.
The conduit hole (1
1
1. Prepare the conduit cord as shown in Figure 1.
2. Install the conduit cord as shown in Figure 2.
1"
3 wire
Knockout surface
For conduit installations, insert the strain relief (not included) into the conduit hole (1
through the body of the strain relief and fasten the ring. Reinstall the bracket.
Installing a 3-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and voltage. Connect the wires as
described below.
• The wire you use, the location and enclosure of splices, etc., must conform to good wiring practices and local codes.
1. Loosen the 3 lower terminal screws from the terminal block.
2. Insert the center bare wire (white/neutral) tip through the bottom
center terminal block opening. On certain models, the wire will
need to be inserted through the ground strap opening and then
into the bottom center block opening.
3. Insert the two side bare wire tips into the lower left and the
lower right terminal block openings.
4. Tighten the screws until the wire is firmly secured (35 to 50
inch-lbs.). Do not over-tighten the screws since it could damage
the wires.
5. Go to step 5 on page 27 to continue with the installation.
CAUTION
CAUTION
Live 1 - Neutral
Live 2 - Neutral
Live 1 - Live 2
/
") must be used.
8
Figure 1
/
"
1"
3
3
8
3
/
"
3
/
"
1
1
2
2
4 wire
Conduit connection plate
You must check voltage after connecting power cord.
120 V
120 V
208 V / 240 V
English - 27
1
/
"
1
8
1
/
"
1
3
1
8
/
"
8
1
Neutral
terminal
Black
Live 1
Black
1
/
"
3
8
/
"
8
Figure 2
Ring
Body
Strain relief
/
"). Then thread the conduit cord
8
Ground
strap
White
Red
White
Red
Wire tips
Live 2