35
Specifications
Input Voltage...................230-240 VAC, 50 Hz
Max. Pull Force ..............650 N (LM60), 800 N (LM80), 1000 N (LM100)
1300 N (LM130)
Standby Power
(door fully closed)...........0.8 W
Motor
Type................................DC gearmotor permanent lubrication
Noise level......................54dB
Drive Mechanism............Belt/Chain
Length of Travel..............Adjustable
Opening speed, up to ....160 mm/s (LM60), 200 mm/s (LM80, LM100)
130 mm/s (LM130)
Lamp...............................On when door starts, off 2-1/2 minutes
after stop.
Door Linkage ..................Adjustable door arm. Pull cord trolley release.
Safety
Personal .........................Push button and automatic stop in down
direction. Push button and automatic stop in
up direction.
Electronic........................Automatic force adjustment
Electrical .........................Transformer overload protector and low
voltage push button wiring.
Limit Device ....................Mechanical RPM/Passpoint detector.
Limit Adjustment .............Electronic
Soft-Start / Soft-Stop........all
Dimensions
Length (Overall)...............3200 mm
Headroom Required .......30 mm
Hanging Weight ..............~12 kg
Receiver
Memory Registers ..........180
Operating Frequency.......6-Band (433 MHz / 868 MHz)
Max. door weight and door types depend on local building and electrical
regulations, rail length, accessories used and door condition.
Please contact us on www.liftmaster.eu or your dealer if you have
further questions.
36
Service parts / Warranty
Your statutory rights are not affected by this manufacturer's warranty.
Please see www.liftmaster.eu/warranty for terms of warranty.
37
Declaration of conformity
Declaration of conformity
The listed automatic garage door opener corresponds to the
applicable sections of the standards EN 55014-1 (2006), EN
55014-2 (2008), EN 61000-4-2 (2009), EN 61000-4-3 (2008),
EN 61000-4-4 (2004), EN 61000-4-5 (2007), EN 61000-4-6
(2009), EN 61000-4-11 (2004), EN 62233 (2008), EN 300220-
1 (V2.3.1),
EN 300220-2 (V2.1.2), EN 60335-1 (2010), EN 60335-2-95
(2004) in accordance with the provisions and all amendments
to the European Directives 2004/108/EC, 2006/95/EC,
2006/42/EC and 1999/5/EG.
Model: ....................................... LM60, LM80, LM100, LM130
S./N.: ............................................xxxxx000001 - xxxxx99999
Manufacturer ...........................................Chamberlain GmbH
..............................................Alfred-Nobel-Str. 4
.......................................D-66793 Saarwellingen
All technical archive data for the opener and the associated
accessories are kept safe by Chamberlain GmbH and will be
provided to the authorities on request if required.
B. P. Kelkhoff
Manager, Regulatory Affairs
Chamberlain GmbH
Alred-Nobel-Str. 4
D-66793 Saarwellingen
January 2015