Descargar Imprimir esta página

Ryobi P2809 Manual Del Operador página 16

Ocultar thumbs Ver también para P2809:

Publicidad

Idiomas disponibles

Idiomas disponibles

Cleaning the nozzles:
 If the nozzles becomes clogged, remove the nozzle
selector.
 Soak entire nozzle selector in warm soapy water.
 If clogs persist, follow the instructions above for removing
nozzles.
 Soak the nozzles in warm, soapy water then blow out
with pressurized air to remove blockage.
When not properly cleaned, the sprayer nozzles may develop
residual chemical build up. This could result in decreased
pressure and spray patterns.
To reduce the chance of blockage, spray a tank of water
through the unit after each use to rinse out any residual
chemical build up that may have occurred.
PROBLEM
Unit has trouble priming /
doesn't spray when tank is
filled.
Unit sprays improperly.
Unit is "spitting".
Spray is weak.
Unit runs for a short period
then shuts off.
This product has a Three-year Limited Warranty
for residential and commercial indoor and outdoor use.
For warranty details, visit www.ryobitools.com
MAINTENANCE
TROUBLESHOOTING
POSSIBLE CAUSE
Pump has lost its prime.
Nozzle is clogged or fluid in
tank is low.
Liquid in tank is too thick.
Solution is too thick.
Battery needs charging.
Solution is too thick.
or call (toll free) 1-800-525-2579.
12 — English
REMOVING/REPLACING THE ANTI-STATIC
STRAP
See Figure 17.
The anti-static strap should not be worn while performing
maintenance.
To remove the strap:
 Turn electrostatic function off and remove the battery
from the unit.
 Use a T15 bit (not included) to remove the two cover
screws.
 Remove the cover.
 Detach the snap connector.
To replace the strap:
 Attach the strap to the unit by attaching the snap connector
to the snap fastener.
 Reinstall the cover.
 Tighten the cover screws.
SOLUTION
Turn the nozzle selector dial to the largest micron setting.
Once spray begins, release the switch trigger and rotate
the nozzle selector dial to the desired position.
Make sure there is sufficient fluid in the tank.
Clean nozzles.
Empty the tank, clean both the tank and filter, then try
again. Make sure that all chemicals/liquid used in the
sprayer are as thin as water.
Make sure that all chemicals/liquid used in the sprayer
are as thin as water.
Recharge the battery.
Make sure that all chemicals/liquid used in the sprayer
are as thin as water.

Publicidad