OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the "off"
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass
strike somebody's face during the process of lighting this unit; stand away from the unit for the first
20 minutes after igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
heating item.
To Light
1.Make sure the control knob (M) is in the"OFF" position.
2.Open the door (C) and slowly open the valve on the propane gas tank by turning the knob
counterclockwise.
3.Close the door (C) on the body.
4.Push the ignition control knob in fully and rotate about 1/4 turn counterclockwise until a
click is heard, it may take several attemps to light the burner.
5.If ignition doesn't occur within a few seconds,release the control knob (M) and rotate to
the"OFF" position. Wait for 5 minutes for gas to clear and then repeat the above lighting
instructions.
6.To adjust the flame, turn the control knob (M) either clockwise or counterclockwise
depending on whether you want to lower or raise the flame.
To Extinguish
1.Turn control knob (M) clockwise to the "HIGH" position; push and continue turning the
control knob (M) to the "OFF" position.
2.Close the cylinder valve on the propane gas tank if you don't intend to use it for a long time.