1. Frame in rough opening. Use dimensions
shown in Figure 9 for the rough opening.
If installing in a corner, use dimensions
shown in Figure 10 for the rough opening.
The height is 26
the wall opening above.
2. Carefully set fireplace in front of rough
opening with back of fireplace inside wall
opening.
3. Attach gas line to fireplace gas regulator.
See Connecting to Gas Supply, page 13.
4. Check all gas connections for leaks. See
Checking Gas Connections, page 15.
3/4" Clearance to Facia
1
/
" Clearance to Sides, Back and Top
3
8
Note: Height of fireplace opening on facia to be 23
Figure 7 - Clearance to Combustibles
Note: All vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf. All
measurements
are in inches.
Side of
Firebox
Figure 8 - Fireplace Clearances
200084-01A
INSTALLATION
/
", which is the same as
1
2
27
/
"
3
4
28
/
"
3
4
Mantel
10"
Shelf
8"
6"
2
/
"
1
2
www.sureheat.com
IMPORTANT: When finishing your firebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc, must have 1/2" clearance to the sides
and top of the firebox. Combustible materials
should never overlap the firebox front.
23.25"
Figure 9 - Rough Opening for Wall
/
"
1
4
Figure 10 - Rough Opening for Corner
28.75"
Installation
Installation
11