PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure
15, page 15).
2. Open main gas valve located on or near
gas meter for natural gas or open pro-
pane/LP supply tank valve.
3. Make sure control knob of heater is in the
OFF position.
4. Check all joints from equipment shutoff
valve to control valve (see Figure 16 or
WARNING: Failure to posi-
tion the logs in accordance with
these diagrams or failure to use
only parts specifically approved
with this heater may result in
property damage or personal
injury.
CAUTION: After installation,
and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to high, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact-
ing logs will create soot.
1. Install log 1 onto the two slots in the middle
plate (see Figure 18).
2. Install log 2 onto the two slots in the left
plate (see Figure 18).
3. Install log 3 onto the two slots in the right
plate (see Figure 18).
4. Install the recessed hole on the bottom of
log 4 onto the pin on log 1 and place onto
log 3 (see Figure 19).
5. Install the recessed hole on the bottom of
log 5 onto the pin on log 1 and place onto
log 2 (see Figure 19).
IMPORTANT: Make sure logs do not cover
any burner ports. It is very important to install
the logs exactly as instructed. Do not modify
logs. Use only logs supplied with heater.
16
INSTALLATION
17, page 15). Apply a noncorrosive leak
detection fluid to all joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Light heater (see Lighting Instructions on
page 18). Check all other internal joints
for leaks.
7. Turn off heater (see To Turn Off Gas Ap-
pliance, page 19).
INSTALLING LOGS
Figure 18 - Installing Logs 1, 2 and 3
Burner
Ports
Figure 19 - Installing Logs 4 and 5
www.sureheat.com
Log #1
Log #2
Log #4
Log #3
Log #5
200084-01A