7. Maintenance and cleaning
Maintenance
Cleaning
8. Technical data
Models
Power supply
Dimensions (WxHxD)
Weight
Power input
Construction material (body)
Working in continuous
Settable restart modality
Maximum load on the plate
General features
Noisiness
Environmental temperature admitted
Storage temperature admitted
Max humidity
Level of electrical protection CEI EN60529
Overvoltage category
Pollution degree CEI EN61010-1
Max altitude
Heating output
Heating plate dimensions
Programmable temperature range
Type of temperature control
Temperature selection
Heating plate
Reading temperature resolution
Hot plate alarm
Overtemperature alarm
Construction material (plate)
Full scale temperature range
Safety circuit
Type
Temperature control type
Programmable temperature range
Temperature selection
Reading temperature resolution
External Probe
Accuracy
Calibration
Position alarm
Overtemperature alarm
Electrical data
Stirring capacity
Programmable speed range
Motor type
Speed selection
Stir
Autoreverse
Autoreverse selection
Full scale speed range
Stirring alarm
Motor rating output
Timer
Timer selection
Timer
2 modalities
Motor counter
Counters
Heating plate counter
No routine or extraordinary maintenance is necessary ;
Repairs must be carried out by authorized Velp personnel only ;
Instrument must be transported in its original packaging any indications present on the original packaging
must be followed (e.g. palletized);
It is the responsibility of the user, to properly decontaminate the unit in case of hazardous substances
remaining on the surface or interior of the device. If in doubt about the compatibility of a cleaning or
decontamination product, contact the manufacturer or distributor.
Disconnect the unit from the power supply and use a cloth dampened with an non-inflammable non-
aggressive detergent.
F20500460, F20500461
230 V / 50-60 Hz (+/-10%)
160x105x280 mm (6.5x4.1x11 in)
2.6 Kg (5.7 lb)
630W, 2,7A
Aluminium body –Technopolymer
enclosure
Admitted
Stop or work
25kg
<< 80 dBa
+5...+40 °C
-10...+60 °C
80%
IP 42
II
2
2000 m
600 W
Ø 135mm
0 - 370 °C
Digital
1 °C
1 °C
Over 50°C
Over 430°C
Aluminium
From 50°C to 370°C
Separated with dedicated probe
Pt100 Class A – Ø 3mm
2 modalities: Fine, Fast
0 – 300°C
1°C
1°C
+/- 1°C*
Da -10.0 a +10.0°C
Not inserted in the sample
310°C
5 Vdc – 1W (max)
20 l di H
O
2
30 – 1700 rpm
BLDC
5 rpm step
From 5s to 99m:59s
1 s
From 100 to 1700 rpm
Motor fault
10 W
From 1min to 99h:59min
1 min
Immediate start or at temperature
set point
Hours of work
Hours of work
9
F20510460, F20510461
115V / 60 Hz (+/-10%)
160x105x280 mm (6.5x4.1x11 in)
2.6 Kg (5.7 lb)
630W, 5,5A
Aluminium body –Technopolymer
enclosure
Admitted
Stop or work
25kg
<< 80 dBa
+5...+40 °C
-10...+60 °C
80%
IP 42
II
2
2000 m
600 W
Ø 135mm
0 - 370 °C
Digital
1 °C
1 °C
Over 50°C
Over 430°C
Aluminium
From 50°C to 370°C
Separated with dedicated probe
Pt100 Class A – Ø 3mm
2 modalities: Fine, Fast
0 – 300°C
1°C
1°C
+/- 1°C*
Da -10.0 a +10.0°C
Not inserted in the sample
310°C
5 Vdc – 1W (max)
20 l di H
O
2
30 – 1700 rpm
BLDC
5 rpm step
From 5s to 99m:59s
1 s
From 100 to 1700 rpm
Motor fault
10 W
From 1min to 99h:59min
1 min
Immediate start or at temperature
set point
Hours of work
Hours of work