With the machine is a die set table packed that indicates the correct
crimping measurement interval for every die set. Crimping measurements
Turn the adjusting knob so that the zero (0) on the dial is lined-up with the
zero (0) on the scale. If zero (0) is set, the machine will crimp the smallest
diameter provided in the interval. Every revolution of the knob increases
the value on the scale with one unit. One turn clock-wise corresponds to
0.1mm on the crimping measurement. The measurement shall be added to
For example: Crimping 16 mm hose requires die nr 16 with the adjusting
knob set to zero (0) and lined up with zero (0) in the window. Crimping 22,2
mm hose recommends die nr 19 with the adjusting knob turned 3 (three)
clock-wise rotations until 3 (three) on the scale and the 2 (two) on the dial is
The set crimping measurement values can differ slightly from the actual
crimping measurement because the machine's die expansion and retraction.
SETTING CRIMPING MEASUREMENTS
that lie outside of the interval are not recommended.
the least-specified diameter in the interval.
lined up with the zero (0) line on the scale.
Compensate this by adjusting the setting.