3
Installing your wall mount
In this chapter, the basic steps to get you started
are described.
Warning
B
Carefully read the safety precautions
in "Section  Important" before you
install the wall mount.
3. Mounting the wall plate (drywall)
Warning
B
For safety reasons, this mount must
be secured to two adjacent wood
studs at least 6" apart. The studs
must be capable of supporting the
combined weight of the mount and
display.
See enclosed mounting template for
1
diagram and guide of how to mount
properly on the wall.
Using a stud finder, locate and mark two
2
adjacent studs for securing the mount
(make sure your marks are in the center
of each stud). You can use your own stud
finder or the one included in the hardware
kit.
D
Note
Once studs have been located you will
need to verify with a hammer and a
nail
A) S imply place the nail over your
mark on the wall and tap in with
hammer. If the nail encounters
resistance and is secure in wall you
have verified a stud location
B) If the nail just pushes through with
no resistance you will need to start
over and locate the stud.
Using the enclosed mounting template,
3
place the diagram against the wall and mark
four locations (two per stud) on the wall
where the mount is to be installed. Be sure
to use the center of each stud.
With the help of another person, place the
4
mount against the wall and level it using the
bubble guide.
While another person holds the mount
5
in place, mark four locations (two per
stud) on the wall where the mount is to
be installed. Be sure to use the center of
each stud. (these marks should line up with
the ones made in step 3 above using the
template).
Set the mount aside and drill a 1/4" (6 mm)
6
pilot hole at each marked location.
Place the mount back against the wall and
7
secure it using the lag bolts (Q) and lag bolt
washers (R) provided. Do not over-tighten
these bolts and do not release the mount
until all bolts are in place.
Once all (4) lag bolts are in place you must
8
tighten each one. (note: be sure not to over
tighten).
1
3. Mounting the wall plate (concrete)
B
Warning
For safety reasons, the concrete wall must
be capable of supporting the combined
weight of the mount and display.
See enclosed mounting template for
1
diagram and use enclosed mounting
template as a guide for precision mounting.
1
5