1. Introduction
R10-CRX is a control unit developed to control up to 10 rolling shutters in an easy and intuitive way.
This product controls motors up to 230 Vac up to 1000 W.
A courtesy light output and an input for the photocells are available.
The product is compliant with transmitters SUN.
A pause time before the automatic closing is available and can be set from 1 to 60 s.
2. Setting
-
RUN TIMER
LED
POWER ON
PHOTO
STOP
S
AD-
A*A+
Avoid putting the connection cables of buttons, security devices and inputs close to those of the power supply of the control unit and of the motor.
Some parts of the control unit are subject to dangerous voltage.
The control unit must be installed and programmed only by qualified professionals.
Always use a device that ensures the disconnection of all poles of the control unit's power supply.
This device can be a switch (connected directly to the power supply terminals) with a contact's minimum distance of 3 mm for each pole, or it can be a device connected to the power network.
For connecting the card and the motors we recommend to use cables with double isolation as imposed by the laws in force; the minimum cross section of the single conductor must not be less than
1mm² and not more than 2.5mm².
The presence of a dampness or metal parts in the walls nearby may negatively influence the capacity the system; it is therefore important to carefully put the aerial and the transmitters away from
walls and/or metal structures, away from the ground and not on the ground.
A tuned aerial is needed to maximize the performances in terms of the range; the range would only be a few meters without it.
If the cable supplied is too short, then do not join an extension to it, but replace the whole cable with one of the right length whose impedance is 50 Ω (RG 58 type).
The aerial cable should never be longer than 10 meters.
⚠
READ THE INSTRUCTIONS FIRST BEFORE YOU INSTALL THE CONTROL UNIT !!!
DEADMAN OPEN
IMPULSE OPEN
DEADMAN CLOSE
IMPULSE CLOSE
ADJ RUN TIMER
INFINITE RUN TIMER
OPEN FUNCTION
GO FUNCTION
+
RADIO LEARN
P1
1
2
3 4
5
6
+
24Vdc
STOP COM OPEN CLOSEPHOTO
NC
NO
C
S
AD-
A*A+
GND ANT
17 18
TRASF
T 6,3A
8
9
10
7
L
PE
230Vac
-
o/ou/or
120Vac
WARNINGS AND ADVICES
18
RAD1
11
12 13 14 15 16
U W V
N
N
L
L
N
L
MOTOR
LIGHT
BZ