Descargar Imprimir esta página

RIB R10-CRX Manual De Instrucciones página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Electrical connections
The control unit is supplied with all the inputs normally closed and jumpered to the common.
Before connecting a device to the control unit remove the jumper corresponding to the device that you want to connect leaving the others unchanged.
17
GND
18
ANT
11
N
230Vac o/ou/or 120Vac
10
L
16
L
LIGHT
15
N
14
V
L
13
W
L
12
U
N
COM
2
1
STOP
OPEN
3
2
COM
CLOSE
4
2
COM
PHOTO
5
2
COM
7
-
24Vdc
6
+
4. Signalling led
"POWER ON": lighted when the control unit is powered.
"PHOTO": lighted if the photocell contact is closed.
"STOP": lighted if the contact stop is closed.
Connect the aerial cable.
Central wire to terminal 18
Shield to terminal 17
Connections already done, coming from the motors management
board.
Connect the power cable between terminals 1 and 2 of the engines
management board.
Connect an eventual courtesy light between the clamps 15 and 16
of the control unit.
Connect the flasher between 12 and 13 (U-W) and set a working
time with the RUN TIMER trimmer (DIP 3 OFF).
Connections already done, coming from the motors management
board.
Connect the NORMALLY CLOSED contact of the STOP to the clamp 1
and 2 of the terminal board.
WARNING : jumper the input 1 to the input 2 if not used.
Connect the OPEN button between the clamp 2 and 3 of the
terminal board.
Leave it opened if not used.
Connect the CLOSE button between the clamp 2 and 4 of the
terminal board.
Leave it opened if not used.
Connect the NORMALLY CLOSED contact of the photocell (PHOTO)
between the clamp 2 and 5 of the control unit.
WARNING: jumper the input 2 to the input 5 if not used.
Connect the power supply of the accessories to the clamp 6 and
7 of the terminal board.
A piece of wire is already present in terminal 18, and this can guarantee an
acceptable range for the radio signal.
Power supply 230 Vac 50 Hz
Do not connect the card directly to the electric network.
Put a device which can ensure the disconnection of each pole from the power
supply of the control unit.
Connecting a charge of 230 Vac 500 W MAX it is possible to light up the
operating zone of the automation during each motion.
The turning off is timed with a period of 3 minutes.
The counting is reset at each impulse of up or down.
Check that the motor wiring is compliant with the installation.
To do this, follow the procedure of the preliminary checks.
Connect the flasher between 12 and 13 (U-W) and set a working time with the
RUN TIMER trimmer (DIP 3 OFF).
If the STOP input is open, then this causes the immediate stop of all engines.
The activation of the OPEN button gives an opening command to all engines.
If DIP 1-2-4 ON, OPEN command and the remote control manage the OPEN-
STOP-CLOSE sequence.
The activation of the CLOSE button gives a closing command to all engines.
The PHOTOCELL (PHOTO) can cause the STOP of the automation or the motion
inversion.
See chap.9
WARNINGS: the control unit gives a voltage of 24 Vdc.
19
G
B

Publicidad

loading

Este manual también es adecuado para:

Abj0015Abj0016