2. CONNECT ELECTRICAL:
For connection to the power supply refer to the following Fig.13:
1. Remove the power supply cover by undoing the (2) screws Fig.13A.
2. Break through the hole on the box cover.
3. Secure the power supply conduit to the cover.
4. Connect the wires of the hood to those of the power supply as described Fig.13B:
BLACK = L line
WHITE = N neutral
GREEN/YELLOW = G ground
- A double-pole switch properly rated must be installed to provide the range hood
power supply disconnection.
- Connect the electrical conduit to the Field Wiring Compartment using listed conduit
fittings.
A
B
Fig.13
Fig.14