Descargar Imprimir esta página

Frigidaire FGGH3047VD Instrucciones De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

30" GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
Provide proper fuel type
Before proceeding: Your range is factory preset to operate
on natural gas. If L.P. conversion is needed, contact your
local L.P. Gas provider for assistance.
The L.P. conversion kit may be located on the lower rear
back panel of the range. If no L.P. kit is provided, contact
your product dealer to obtain the correct L.P. conversion
kit.
Installation of this range must conform with local codes
or, in the absence of local codes, with the National
Fuel Gas Code ANSI Z223.1—latest edition when
installed in the United States.
When installed in a manufactured (mobile) home,
installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part
3280 [formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD (Part 280)] or,
when such standard is not applicable, the Standard
for Manufactured Home Installations, ANSI/NCSBCS
A225.1, or with local codes.
This range has been design certified by CSA
International. As with any appliance using gas and
generating heat, there are certain safety precautions
you should follow. You will find them in the Use & Care
Guide, read it carefully.
Be sure your range is installed and grounded properly
by a qualified installer or service technician.
This range must be electrically grounded in
accordance with local codes or, in their absence, with
the National Electrical Code ANSI/NFPA No .70—
latest edition when installed in the United States. See
Grounding Instructions on page 9.
Before installing the range in an area covered with
linoleum or any other synthetic floor covering, make
sure the floor covering can withstand heat at least
90°F above room temperature without shrinking,
warping or discoloring. Do not install the range over
carpeting unless you place an insulating pad or sheet
of 1/4-inch thick plywood between the range and
carpeting.
Make sure the wall coverings around the range can
withstand the heat generated by the range.
Do not obstruct the flow of combustion air at the oven
vent nor around the base or beneath the lower front
panel of the range. Avoid touching the vent openings
or nearby surfaces as they may become hot while the
oven is in operation. This range requires fresh air for
proper burner combustion.
Air curtain or other overhead range hoods, which
operate by blowing a downward air flow on to a range
or cooktop, shall not be used in conjunction with gas
ranges other than when the hood and range have
been designed, tested and listed by an independent
test laboratory for use in combination with each other.
DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING
AN ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO "OFF" IN THE EVENT OF A POWER
FAILURE.
The electric ignitor will automatically re-ignite the oven
burner when power resumes if the oven thermostat control
was left in the "ON" position.
When an electrical power failure occurs during use, the
surface burners will continue to operate.
During a power outage, the surface burners can be lit with
a match. Hold a lighted match to the burner, then slowly
turn the knob to the LITE position. Use extreme caution
when lighting burners this way.
2

Publicidad

loading

Este manual también es adecuado para:

Fggh3047vf