Descargar Imprimir esta página

Frigidaire FGGH3047VD Instrucciones De Instalación página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

30" GAS FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
1. Clearances and Dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b. Location—Check location where the range will be installed. Check for proper electrical supply and gas supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must be
solid and level.
Typical cabinet installation
Front
view
30" Minimum*
5"
Minimum to
wall on either
side of range
above 36" height.
36"
Minimum
Fig.1
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE
TOP OF THE COOKING SURFACE AND THE BOTTOM
OF AN UNPROTECTED WOOD OR METAL CABINET; OR
24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR
METAL CABINET IS PROTECTED BY NOT LESS THAN
1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED
WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM
OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS
THE MINIMUM FOR THE REAR OF THE RANGE. FOLLOW
ALL DIMENSION REQUIREMENTS PROVIDED ABOVE
TO PREVENT PROPERTY DAMAGE, POTENTIAL FIRE
HAZARD, AND INCORRECT COUNTERTOP AND CABINET
CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY
REACHING OVER HEATED SURFACE UNITS, CABINET
STORAGE SPACE LOCATED ABOVE THE SURFACE UNITS
SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE
PROVIDED, THE RISK CAN BE REDUCED BY INSTALLING
A RANGE HOOD THAT PROJECTS HORIZONTALLY A
MINIMUM OF 5" (127 mm) BEYOND THE BOTTOM OF
THE CABINETS.
DO NOT MAKE ANY ATTEMPT TO
OPERATE THE ELECTRIC IGNITION OVEN DURING
AN ELECTRICAL POWER FAILURE. RESET ALL OVEN
CONTROLS TO OFF IN THE EVENT OF A POWER
FAILURE. The electric ignitor will automatically re-
ignite the oven burner when power resumes if the oven
thermostat control was left in the ON position.
30"
Minimum
Minimum to
18"
cabinets on
either side
of range
30"
0" clearance below cooking top and at rear of range
Side
view
13"
Maximum depth
for cabinets
above range top.
25" Max.
L
L
A
T
R
E
W
O
I N
B
A
C
4
Fig.3
When an electrical power failure occurs during use, the
surface burners will continue to operate.
During a power outage, the surface burners can be lit
with a match. Hold a lighted match to the burner, then
slowly turn the knob to the Lite position. Use extreme
caution when lighting burners this way.
4
29
/
"
7
8
36
/
"
5
8
"
±
/
1
4
Maximum
26
/
"
6
8
47"
Fig.2
6
Open space
This space
for gas
must
remain clear
8"
/
"
1
3
12
Gas location
"
24
/
1
8
W
/
"
1
2
A
C
L L
4"
O
A
R
22
/
"
5
8
B
I N
E
T
"
/
1
16

Publicidad

loading

Este manual también es adecuado para:

Fggh3047vf