BTL6-P11 _ -M _ _ _ _ -A1-S115
Magnetostrictive Linear Position Sensor – Profile Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, take it
out of service and secure against unauthorized use.
Downloading further instructions
A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
3)
73
2)
Magnet
BTL6-A-3801-2
~60
1
english
Nominal length
4)
= Measuring range
A
21
18
9
~250
~250
Dimensions and function
The BTL contains the waveguide which is protected by an
aluminum housing. A magnet is moved along the
waveguide. This magnet is connected to the system part
whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
Electrical connection
Pin assignment of S115 (view from
above on BTL connector), 8-pin M12
circular plug
Pin
BTL6-P11_-...
1
+Init
2
+Start/Stop
3
–Init
4
Must remain free
5
–Start/Stop
1)
6
GND
7
20...28 V
8
Must remain free
1) Reference potential for supply voltage and EMC-GND.
3)
73
4)
21
A
Ø 5.5
2)
Bracket
BTL6-A-MF03-K-50
~60
2) Not included in scope of delivery
3) Unusable area
4) Dimensions see section Installation
File No.
E227256
37.6
28
Ø 4.2
16
4)
C
Slot
50
60