TRANSFORMERS - TRANS88 / TRANS150
Installation
Strip and connect the wires to the outlet power terminals
on the back of the transformer. Loosen the screws on the
outlet power terminals and slide the wire under the screw plate.
Tighten the screws to secure the wire.
Mount the Transformer in the desired location.
The Transformer is weather-resistant and must
be mounted above the ground on a wall or post.
Ensure that the power cord is within reach of a properly grounded
Ground Fault Circuit Interrupter (GFCI) equipped outlet.
After all connections to low voltage lights have been completed, plug the input power cord
into the 120 volt GFCI outlet to complete installation.
Operation
The TRANS88 and TRANS150
have a control panel featuring
a rotary timer control switch,
photocell and circuit
breaker/reset button.
The circuit breaker will turn off
power to the lighting system in
case of overload/power surge.
If the circuit is tripped, inspect/repair
the lighting system and depress the reset
button to restore power. The photocell
automatically turns the transformer on when it begins to get dark outside. The photocell does
not need to be in direct sunlight; however it must have access to indirect sunlight to operate
effectively. The timer switch provides several modes of operation. You can choose OFF, ON,
AUTO, 4H, 6H, or 8H.
OFF: Output power is off / system is off
ON: Output power is on / system is on at all times
AUTO: Photo cell will turn the output power on at
dusk and off at dawn
4H: Photo cell will turn the output power on at
dusk and it will turn off after 4 hours
6H: Photo cell will turn the output power on at
dusk and it will turn off after 6 hours
8H: Photo cell will turn the output power on at dusk and it will turn off after 8 hours
INFICOLOR SMART MODULE
Installation
The InfiColor Smart Module is weatherproof, but must be mounted above the ground on a
wall or post within reach of a properly grounded GFCI outlet. Do not submerse the Control
Module or expose it to heavy rainfall.
• Install the Module in a well-ventilated area to ensure that the module operates within its
specified working temperature.
• Verify that the Smart Module input voltage is 12 volt AC. We recommend that you use the
transformer provided with this unit.
6
Outlet Power
Terminals
Circuit Breaker / Reset Button
Photocell Sensor
Timer Control
Input Power Cord
4H
6H
8H
AUTO
ON