2. Gate Closing Limit Position Setting:
b. Press and hold "-" button to enable the gate to run to its appropriate closing limit position. Then release the "-" button to stop running.
Through pressing the "-" or "+" button, the closing limit position can be adjusted accurately. (If the gate runs to its opening direction after
pressing the "-" button, please press "PROG" button to exit the travel limit position setting rst, then exchange the motor wires and
re-start to set the limit position).
c. Press "SET" button to con rm the closing limit position. The indicator lights will be on in sequence from L1 to L5.
3. Gate Opening Limit Position Setting:
d. Press and hold "+" button to enable the gate to run to its appropriate opening limit position, then release the "+" button to stop
running. Through pressing the "-" or "+" button, the opening limit position can be adjusted accurately
e. Press "SET" button to save the settings and exit automatically. The indicator lights L1-L5 will be on for one sec.
5.3.2 Travel Setting Tips:
During the travel setting process, users can check the travel limit position settings though the indicator lights status. (Table 1 Travel
Setting Tips).