Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL QTR140
VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See "Connect Wiring" for details.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or repair
(other than by Broan-NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NU-
TONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the ex-
clusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
MODEL QTR140
Page 

Publicidad

loading

Resumen de contenidos para Broan QTR140

  • Página 1 To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence...
  • Página 2 MODEL QTR140 Page  TYPICAL INSTALLATIONS PLAN THE INSTALLATION ROOF CAP 6-IN. OR 4-IN. ROUND DUCT Housing mounted to I-joists. WALL 6-IN. OR 4-IN. Use I-joist spacer block (provided). CAP Purchase ROUND separately ELBOW The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed.
  • Página 3 MODEL QTR140 Page  INSTALL HOUSING & DUCT CONNECT WIRING 1. Bend housing tabs. Use a pliers to bend housing TABS out to 90 TABS 2. Mount SPACER housing to (use for mounting to I-Joist) joist. Hold housing in place so that the housing tabs contact the bottom of the joist. The housing mounts with four (4) I-JOIST screws or nails.
  • Página 4 MODEL QTR140 Page  INSTALL GRILLE 6. Finish ceiling. Install ceiling material. Cut out around housing. 7. Attach grille to housing. Squeeze grille springs and insert them into slots on each side of hous- ing. 8. Push grille SERVICE NOTE against ceil- To remove Blower Assem- ing. bly: Unplug motor (7). Remove thumbscrew (16) from motor plate (9) flange.
  • Página 5 Nacional de Protección contra Incendios (National Fire Protec- IZACIÓN O IDONEIDAD PARA UN PROPÓSITO PARTICULAR. tion Association, NFPA), la Sociedad Americana de Ingenieros Durante este período de tres años, Broan-NuTone, a su criterio, reparará o de Calefacción, Refrigeración y Aire Acondicionado (American reemplazará, sin cargo alguno, cualquier pieza o producto que se encuentre Society for Heating, Refrigeration and Air Conditioning Engi- defectuoso bajo condiciones normales de uso y servicio.
  • Página 6 MODELO QTR140 Página  INSTALACIONES TÍPICAS PLANIFICACIÓN DE LA INSTALACIÓN TAPA DE TECHO * CONDUCTO REDONDO DE 6 O 4 PULG.* Montaje de cubierta en viguetas “I”. Utilice un taco separador de viguetas “I” (suministrado). TAPA CODO REDON- DE DO DE 6 O 4 Se compran PARED* PULG.* por separado El ventilador funcionará con más eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto más corto...
  • Página 7 MODELO QTR140 Página  CONEXIÓN ELÉCTRICA INSTALE LA CUBIERTA Y EL CONDUCTO 1. Doble las lengüetas de la cubi- erta. Con un alicate, doble las LENGÜE- TAS de la cubierta LENGÜETAS a 90 2. Monte la SEPARADOR (se usa para el montaje cubierta en a la vigueta “I”) la vigueta.
  • Página 8 MODELO QTR140 Página  INSTALE LA REJILLA 6. Termine el cielo raso. Instale el material del cielo raso. Recorte alrededor de la cubierta. 7. Acople la rejilla a la cubierta. Apriete los resortes de la rejilla e insér- telos en las ranuras que se encuentran a cada lado de la cubierta. 8. Empuje la NOTA DE SERVICIO rejilla contra Para desmontar el conjunto el cielo raso. del ventilador: Desenchufe el motor (7).