6.
Function
controlled water flow
6.1
Allow your hand to approach the sensor.
• Water flows.
• The water flow will stop automatically
– once the preset flow time expires
or
– after approaching the sensor once again.
7.
Setting the Flow Duration
You can adjust the flow time from 10 seconds to 5 minutes seconds using the
remote control (not included, see Accessories
8.
Setting the Range
The range for body reflection can be set with the remote control (not included, see
Accessories
Chapter
9.
Hygiene Flushing
☞
At the factory, the hygiene flush function is set so that water flows for 10 seconds 24
hours after the flush was last activated.
The parameters for hygiene flushing can be set with the remote control (not
included, see Accessories
Intervals of 0, 8, 24, 48 or 72 hours can be set for hygiene flushing (0 = hygiene
flushing disabled). The following times can be set for the flow duration:
– 1 x short = 10 s
– 2 x short = 30 s
– 3 x short = 60 s
– 4 x short = 2 min
☞
The flushing duration is factory-set to 10s.
Display for hygiene flushing on the fitting
9.1
Allow your hand to approach the sensor at a distance of about 10 cm for 3 seconds.
9.2
Between the 1st and the 2nd flash of the LED, remove your hand from the sensor.
• Hygiene flushing active: The LED flashes quickly 4 times.
• Hygiene flushing inactive: The LED flashes slowly 2 times.
12).
Chapter
12).
Chapter
12).
– 5 x short = 3 min
– 6 x short = 5 min
– 7 x short = 7 min
– 8 x short = 10 min