Function; Adjusting The Flush Volume - Franke AQRE431 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
!
Caution!
Do not remove the retaining ring.
9.9
Remove the mounting frame from the cover plate by loosening the set screw.
9.10 Screw the mounting frame on horizontally.
9.11 Attach the battery box to the plug.
9.12 Connect the control unit with the battery box.
9.13 Connect the control unit with the solenoid valve cartridge.
9.14 Adjusting the flush volume (see
9.15 Adjusting the flushing flow (see
9.16 Place the cover plate on the frame and clip it behind the two tongues on the
mounting frame.
9.17 Attach the cover plate with the set screw.

10. Function

10.1 Stand in front of the urinal for at least 10 seconds.
10.2 Flushing starts after moving away. A forced flush is activated after 24 hours of non-use.

11. Adjusting the flush volume

11.1 Remove the cover plate.
11.2 Set the flow volume regulator to "fully opened" (see
11.3 Disconnect the battery voltage supply for min. 5 seconds.
The flush volume setting is activated.
11.4 Reconnect the voltage supply.
Wait for the confirmation flashing (1x long 3x short).
11.5 Hang the cover plate.
11.6 Hold your hand a distance of 5 - 10 cm in front of the sensor. The LED flashes quickly.
11.7 After 5 seconds the indicator lamp automatically turns off.
11.8 Remove your hand from the sensor range (min. 60 cm).
11.9 Keep your hand 5 - 10 cm in front of the sensor. The LED flashes.
2 flashes, pause, 3 flashes, pause, 4 flashes, etc.
11.10 Remove your hand from the sensor range (min. 60 cm) after the required flash sequence.
Afterwards the fitting flushes with the set flush volume.
The flash sequence of the corresponding flush volume occurs again after flushing.
11.11 Low flush volume
P: pause
6
chapter
11.).
chapter
12.).
chapter
9.8).

Publicidad

Tabla de contenido
loading

Tabla de contenido