7. Electrical work
Function table
Select unit number 00 [table 1]
Mode
Power failure automatic recovery
Indoor temperature detecting
Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller])
Mode
Filter sign
Fan speed
Up/down vane setting
3D i-See sensor positioning *3
Fan speed during the cooling thermostat is OFF
*1 When the power supply returns, the air conditioner will start 3 minutes or 1 minute later (hinge on Outdoor unit).
*2 Power failure automatic recovery initial setting depends on the connecting outdoor unit.
*3 When the 3D i-See sensor corner panel position changed, change this mode. Refer to page 18.
7.4.3. How to set the fixed up/down air direction
• Only the particular outlet can be fixed to certain direction with the procedures below.
Once fixed, only the set outlet is fixed every time air conditioner is turned on. (Other
outlets follow UP/DOWN air direction setting of the remote controller.)
I Explanation of word
• "Refrigerant address No." and "Unit No." are the numbers given to each air condi-
tioner.
• "Outlet No." is the number given to each outlet of air conditioner.
(Refer to the right.)
• "Up/Down air direction" is the direction (angle) to fix.
Reset
1
2
horizontal
Horizontal airflow
Remote controller setting
The airflow direction of this outlet
is controlled by the airflow direc-
tion setting of remote controller.
12
Settings
Not available
Available
Indoor unit operating average
Set by indoor unit's remote controller
Remote controller's internal sensor
Settings
100Hr
2500Hr
No filter sign indicator
Silent
Standard
High ceiling
Not setting
Draft less setting (vanes angle setup 1)
Downward setting (vanes angle setup 2)
Position 1 ("
" stamp position, page 18)
(Position 1)
Position 3 ("○" stamp position, page 18)
Setting fan speed
Stop
Extra low
3
4
5
Downward
Fixed setting
The airflow direction of this outlet is fixed
in particular direction.
* When it is cold because of direct
airflow, the airflow direction can be fixed
horizontally to avoid direct airflow.
Mode no.
01
*1
02
Mode no.
07
08
11
12
27
Electric component box
Outlet No. 4
Outlet No. 3
Note:
The outlet No. is indicated by the number of grooves on both ends of each
air outlet. Set the air direction while checking the information shown on the
remote controller display.
Air outlet identification marks
Setting no. Initial setting
setting
1
2
Ο
*2
1
Ο
2
3
Setting no. Initial setting
setting
1
2
Ο
3
1
2
Ο
3
1
2
3
Ο
1
2
3
Ο
1
Ο
2
3
Outlet No. 1
Outlet No. 2