Common Power Output Problems
Possible Causes
Battery voltage below 10.5 volts
Equipment being operated draws too much power
Inverter in thermal shutdown condition
AC output is shorted
SERVICE INFORMATION
Black & Decker offers a full network of company-owned and authorized service locations. All
Black & Decker Service Centers are staffed with trained personnel to provide customers with
efficient and reliable power tool service. Whether you need technical advice, repair, or genuine
factory replacement parts, contact the Black & Decker location nearest you.
SPECIFICATIONS
Maximum Continuous Power:
Surge Capacity:
USB Output:
Input Voltage:
Low Voltage Alarm:
Low Voltage Shutdown:
Thermal Shutdown:
Wave Form:
Fuses: Internal:
Input Cables:
Operating Temperature:
Storage Temperature:
Operating/Relative Humidity:
All manuals and user guides at all-guides.com
200 Watts
400 Watts
5 V DC (500mA)
12.8 volts
11.0 ± 0.3 volts DC
10.5 ± 0.3 volts DC
Automatic
Modified Sine Wave (MSW)
25 Amps/DC Accessory Plug: 8 Amps
Battery clip cables and 12V Accessory Plug
10-20°C (50-68°F)
0-40°C (32-104°F)
5-95% non-condensing
27
Recommendations
Recharge battery or check DC power supply.
Reduce load to maximum 200 watts.
Allow inverter to cool down. Ensure there is adequate
ventilation around the unit, and the load is no more
than 200 watts for continuous operation.
Unplug the AC appliance. Disconnect the unit from
any 12 volt DC power source, then reconnect the unit
BEFORE plugging the appliance back in.