INSTALLATION INFORMATION:
Attach the ceiling plate using the included plugs and screws to the ceiling on a location
of choice. Wall mounting is not recommended for smoke detection. Put the 9V block
battery in the smoke detector. Then put the detector to the ceiling plate and, twist
clockwise to lock it in place. Perform a first test by holding the test key for two seconds.
Also see the paragraph: "Testing".
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector works if the 9V battery has been placed and the SA-19/1 has
been mounted to the ceiling. The unit can only be mounted to the plate if the battery
has been installed. The LED underneath the test button will now flash ± every 45 se-
conds. Once smoke is detected, the alarm will sound. Once the smoke disappears, the
smoke alarm will stop automatically
Time-out functie:
Met deze functie wordt de gevoeligheid van het alarm vermindert gedurende
ongeveer 10 minuten. Deze functie kan worden ingeschakeld door één keer op de
"HUSH" knop te drukken. De gevoeligheid van de rookmelder wordt automatisch
verminderd en het indicatielampje zal ± iedere 10 seconden even oplichten om aan te
geven dat het geluid tijdelijk onderdrukt is. Na 10 minuten wordt het alarm weer geacti-
veerd. Als er dan nog rookvorming is zal het alarmgeluid weer te horen zijn.
Deze functie kan herhaaldelijk worden gebruikt.
Test:
Hold the test key for at least 2 seconds. The operation is still correct if you hear 2 or
three signal tones. Check the smoke detectors weekly. In alarm status the smoke de-
tector will generate about 85dB(A). Do not use candles, open fire or cigarettes to test
the smoke detector.
ATTENTION:
•
If the cause of an alarm is unclear, assume it's caused by fire. Immediately
evacuate the building.
•
Keep the smoke detectors out of range of children.
•
Protect against dust during rennovations. Without protection the smoke