ERROR CODES
AS - Humidity sensor error -- Unplug the unit and plug it back in. If error repeats, call for service.
ES - Temperature sensor error -- Unplug the unit and plug it back in. If error repeats, call for service.
P2 - Bucket is full or the bucket is not in correct position -- Empty the bucket and/or adjust it to the proper position.
EC - Please ensure that the room ambient temperature matches the recommended operating temperature for the unit,
5°C (41°F) - 35°C (95°F). If the temperature is within this range, call for service.
INDICATOR LIGHT
FUNCTIONS
IMPORTANT NOTE: Depending on the humidity conditions of the surrounding environment, the dehumidi er may not start
automatically when the "on/off" button is pressed (see dehumidifying mode instructions on page 7 for details).
MEMORY SETTING:
Each time the unit is disconnected/re-connected and/or in the event of a power failure, the electronic circuit board
automatically defaults to the last program setting that was used. After the unit has stopped, it may take several minutes
before operating conditions resume.
AUTO-RESTART:
If the unit shuts off unexpectedly due to a power outage, it will restart with the previous function settings automatically
when the power resumes.
BUCKET FULL INDICATOR LIGHT: When the bucket is full and/or incorrectly positioned inside the cabinet, the bucket
full light will turn on and remain on until the bucket is emptied and/or correctly re-positioned. This condition will result in
the immediate shut down of the dehumidifying system (both compressor and fan motor operation are terminated). This
is a safety feature. When the bucket is emptied and/or correctly re-positioned, the dehumidi er will resume operation
automatically. NOTE: It may take several minutes before operating conditions resume.
AUTO-DEFROST:
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost
disappears.
TIMER
FUNCTIONS
Follow these steps to program the Auto-On or Auto-Off feature using the control panel:
Auto-Off:
1) When the unit is on, and the TIMER button is pressed, the Timer Off indicator light illuminates to indicate that the Auto-
Off program is initiated.
2) Press or hold the UP or DOWN button to change the 'Auto' time by 0.5 hour increments, up to 10 hours (then at 1 hour
increments up to 24 hours). The unit control will count down the time remaining until start.
3) Within 5 seconds of setting Auto Off time, press the TIMER button again to complete the Auto-Off program.
Auto-On:
4) When the unit is off, and the TIMER button is pressed, the Auto-On program is initiated. Set the Auto-On time as in step
2 above. Within 5 seconds of setting Auto-On time, press the TIMER button again to complete the Auto On program.
NOTE: When the Auto On & Auto Off times are set, within the same program sequence, TIMER ON OFF indicator lights
illuminate indicating that both ON and OFF times are now programmed.
NOTE: Turning the unit ON or OFF at any time, changing the On/Off timer setting to 0.0, and a P2 error code will cancel
the Auto-On/Off function.
OPERATION INSTRUCTIONS
6