Adjust High Flame Setting Screw
When converting from LP to Natural gas, you will need to
adjust the high flame setting screw for ideal burner flame
height.
1.
Remove each control knob for the main burners.
2.
Use a flat-blade screwdriver to turn the high flame
setscrew counterclockwise approximate 90º.
3.
Check that burner operates at the new high flame setting.
It may be necessary to adjust the screw setting slightly
more to get the ideal burner flame height.
4.
Place the burner control knobs back to their original
positions.
Record Conversion
The LP appliance nameplate is located inside the grill cabinet
on the left-hand side. Once converted, place the NG appliance
nameplate as close as possible to the current LP appliance
nameplate without covering it.
In the last page of the Use and Care Guide, write "Converted to
Natural Gas". Also, record the conversion date and the
technician/company that performed the conversion.
44