Descargar Imprimir esta página

Daikin Altherma 3 H MT ECH2O ETSH12P50EF Manual De Instalación página 43

Ocultar thumbs Ver también para Altherma 3 H MT ECH2O ETSH12P50EF:

Publicidad

S4S
# Entrada de alimentación de red inteligente
S6S~S9S
* Entradas digitales de limitación energética
S10S~S11S
# Contacto de red inteligente de baja tensión
S12S
Entrada del medidor de gas
S13S
Entrada solar
TR1
Transformador de suministro eléctrico
X*, X*A, X*Y, Y*
Conector
X*M
Regleta de conexiones
* Opcional
# Suministro independiente
Traducción de texto de diagrama de cableado
Inglés
(1) Main power connection
Outdoor unit
SWB1
(2) User interface
Only for remote user interface
SD card
SWB1
WLAN cartridge
WLAN cartridge option
WLAN adapter module option
(3) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC Control Device
230 V AC supplied by PCB
Alarm output
BUH option
BUH option only for *
Bizone mixing kit
Continuous
DHW Output
DHW pump
DHW pump output
Electrical meters
Ext. ambient sensor option
(indoor or outdoor)
Ext. heat source
For external power supply
For HP tariff
For internal power supply
For HV smartgrid
For LV smartgrid
For safety thermostat
For smartgrid
ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663479-1 – 2021.07
Traducción
(1) Conexión de alimentación
principal
Unidad exterior
Caja de interruptores
(2) Interfaz de usuario
Solo para la interfaz de usuario
utilizada como función de
termostato ambiente
Ranura de tarjeta para cartucho
WLAN
Caja de interruptores
Cartucho WLAN
Opción de cartucho WLAN
Opción de módulo adaptador
WLAN
(3) Opciones de suministro
independiente
Detección de pulsos CC 12 V
(tensión suministrada por la
PCB)
Dispositivo de control de
230 V CA
230 V CA suministrados por PCB
Salida de alarma
Opción de resistencia de reserva
Opción de resistencia de reserva
solo para *
Kit de mezcla bizona
Corriente continua
Salida de agua caliente sanitaria
Bomba de agua caliente sanitaria
Salida de bomba de agua
caliente sanitaria
Medidores eléctricos
Opción de sensor ambiente
externo (interior o exterior)
Fuente de calor externa
Para suministro eléctrico externo
Para tarifa de la bomba de calor
Para suministro eléctrico interno
Para red inteligente de alta
tensión
Para red inteligente de baja
tensión
Para termostato de seguridad
Para red inteligente
Inglés
Gas meter
Inrush
Max. load
Normally closed
Normally open
Note: outputs can be taken from
terminal positions
X12M.17(L)-18(N) and
X12M.17(L)-11(N).
Max. 2 outputs at once are
possible this way.
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
Smartgrid contacts
Smartgrid feed-in
Solar input
Space C/H On/OFF output
SWB1
(4) Option PCBs
Only for demand PCB option
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
SWB
(5) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
(6) Backup heater power supply
Only for ***
SWB2
10 Datos técnicos
Traducción
Medidor de gas
Corriente de irrupción
Carga máxima
Normalmente cerrado
Normalmente abierto
Nota: las salidas pueden tomar
como referencia las posiciones
de los terminales
X12M.17(L)-18(N) y
X12M.17(L)-11(N).
De este modo es posible utilizar
2 salidas a la vez.
Contacto de suministro eléctrico
de flujo de kWh preferente:
detección de 16 V CC (tensión
suministrada por PCB).
Contacto de termostato de
seguridad: detección de 16 V CC
(tensión suministrada por PCB)
Válvula de aislamiento
Contactos de red inteligente
Entrada de alimentación de red
inteligente
Entrada solar
Salida de ENCENDIDO/
APAGADO de la calefacción/
refrigeración de habitaciones
Caja de interruptores
(4) PCB de opciones
Solo para la opción de PCB de
demanda
Entradas digitales de limitación
energética: detección 12 V CC /
12 mA (tensión suministrada por
PCB)
Caja de interruptores
(5) Termostatos de
ENCENDIDO/APAGADO externo
y convector de la bomba de calor
Zona de temperatura del agua de
impulsión adicional
Zona de temperatura del agua de
impulsión principal
Solo para sensor externo (suelo
o ambiente)
Solo para convector de la bomba
de calor
Solo para termostato de
ENCENDIDO/APAGADO con
cable
Solo para termostato de
ENCENDIDO/APAGADO
inalámbrico
(6) Suministro eléctrico de la
resistencia de reserva
Solo para ***
Caja de interruptores
Manual de instalación
43

Publicidad

loading