5.4.3 Exemplary settings
Example 1 is the factory setting (since factory settings are entered by computer, all DIP
switches of a new product are set to 'off').
DS-1 3 position switch
DS-2 Charge voltage
DS-3 Charge voltage
DS-4 Frequency
DS-5 Search mode
DS-6 Store setting
Example 1: (factory setting)
1
No 3 position
switch connected
2, 3
GEL 14.4 V
4
Frequency: 50Hz
5
Search mode off
6 Store setting: off→ on→ off
Store the settings by changing switch ds-6 from off to on, and then back to off.
The LEDs 'charger' and 'alarm' will flash to indicate acceptance of the settings.
6. MAINTENANCE
The Multi does not require specific maintenance. It will suffice to check all connections once
a year. Avoid moisture and oil/soot/vapours, and keep the device clean.
off
DS-1
off
off
DS-2
off
DS-3
off
off
DS-4
off
off
DS-5
off
DS-6
Example 2
1
No 3 position
switch connected
2,3
AGM 14,7V
4
Frequency: 50Hz
5
Search mode off
6 Store setting: off→ on→ off
19
DS-1
on
DS-2
DS-3
DS-4
DS-5
DS-6
Example 3
1
2, 3
4
5
6 Store setting: off→ on→ off
on
on
on
on
on
3 position
switch connected
Tubular plate 15V
Frequency: 60Hz
Search mode on