CoDe
PoSSIBLe CAuSe
15
Extension cord is wrong length or gauge
16
Loose electrical connections
17
Possible defective motor.
18
Fuse blown, circuit breaker tripped
Tank pressure exceeds pressure switch cut-in pressure
19
PoSSIBLe SoLutIon
Check for proper gauge wire and cord length. See
extension Cords under Installation.
Contact a D
WALT factory service center or a D
e
authorized service center.
Contact a D
WALT factory service center or a D
e
authorized service center.
1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit
breaker with higher rating than that specified for your
particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.