Descargar Imprimir esta página

HT Italia HT4003 Manual De Instrucciones página 3

Pinza 400a

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL
This note must be read in full. Any operations on live conductors can be dangerous.
The operator is expected to be fully aware of all necessary electrical safety regulations and
procedures. Safe operation is this responsibility.
Never exceed the limit of Voltage (600V) or current (400A) indicate in this manual.
When measuring current, if strong current nears to the clamp jaw, it will affect the
accuracy.
While measuring current, always put the tested conductor in the center of clamp jaw so as
to obtain a more accurate reading.
It is up to the user to ensure that the equipment is at all times in its original safe conditions.
Strong vibrations and impacts may cause damage to the instrument..
SPECIFICATIONS
Measuring Range:
Output (max):
Ratio:
Minimum load:
Frequency Range:
Safety:
Pollution degree:
Operating Temperature/Humidity: -10 ÷ +50 °C
Storage Temperature/Humidity:
Overvoltage Catagory:
Max Diameter Cable:
Dimension (mm):
Weigh:
Output connector:
Power Measurement:
ACCURACY
Current Range
Output Range
1 - 400A
MEASUREMENT PROCEDURE
1. Before start the test, take all precautionary measures for operator's safety (electrical protection gloves,
etc.).
2. Even if it is possible to insert / remove energized conductors from the jaws (symbol
possible) the conductors under test.
3. Connect clamp's output terminals to the inputs of the instrument to be used as indicator.
4. Open the clamp and put the tested conductor in the center of the clamp jaws, (no gap is allowed between
the connections of clamp jaws).
5. Read the current value in the indicator's display.
CAUTION: this symbol indicates that equipment and its accessories shall be subject to a
separate collection and correct disposal.
1A ÷ 400A
400mV
1A / 1mV
10kΩ
40Hz ÷ 5000Hz
EN61010 (EN61010-1, EN61010-2-031, ENC61010-2-032)
2 according IEC 1010-1
-10 ÷ +60 °C
III 600V
Φ 30 mm
195 x 64 x 30 mm
195 g
2 safety banana
Take care about conventional power direction (see picture on side)
1mV – 400mV
SAFETY WARNING
Accuracy
±(1.5% Reading+0.5A)
(40Hz~60Hz)
±(2.0% Reading +0.5A)
(61Hz~5kHz)
EN -1
HT4003
Overload protection
600Arms
(max 60 seconds)
), de-energise (if

Publicidad

loading