KEMPER Filter-Master XL Operating Instructions - EN
2.5 Safety instructions for maintenance and defect removal for the
Filter-Master XL
Setting up, maintenance and repair work and troubleshooting must be performed
only when the device is switched off.
Always tighten bolt connections that have been loosened during repair work! If
specified, tighten the relevant bolts with a torque wrench.
In particular, clean dirt and cleaning products off connections and threaded couplings
before beginning maintenance / repair / care work.
Prescribed intervals for regular maintenance work or such intervals specified in the
operating instructions must be observed!
Before disassembling, mark the parts that belong together.
2.6 Notes regarding special types of hazard
Electrical Systems
Work on the electrical equipment of the filter device may only be carried out by
a trained electrician or by trained personnel under the guidance and supervision
of a skilled electrician in accordance with electrotechnical regulations!
Before opening the device, disconnect the power supply and secure it against
unintentional reconnection.
In the event of faults in the electrical power supply of the filter device, immediately
push the On/Off switch of the filter device and disconnect the power supply!
Use only original fuses with the prescribed amperage!
Electrical components, on which inspection, maintenance and repair work must be
carried out, must be disconnected from the power supply. Secure resources which
have been activated against unintentional or automatic reconnection. Firstly check
that no voltage is present in activated, electrical components, then isolate adjacent
components under voltage. When making repairs, ensure that constructive
characteristics are not altered in a way that reduces safety.
Check cables regularly for damage and replace if necessary.
Noise
The A-weighted equivalent sound pressure level of the filter unit is LpA ≤ 69 dB(A).
A higher sound pressure level at the location of the filter unit may result due to other
machines and/or by the local circumstances. In this case, the operator is obliged to
provide the operating personnel with the appropriate protective equipment.
- 51 –
Technical changes and errors excepted.