Figure 6, Filter Cartridges Bracket - Kemper Filter Master XL Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 167
Changing the filter element:
For the filter cartridge change, please use the disposal bag which is included in the
scope of delivery of the replacement cartridge.
You will also need a breathing mask, protective clothing and gloves in order to avoid
contact with dust.
• Turn the device off and disconnect the power supply.
• Disconnect the device from the supply of compressed air.
• Put on protective clothing and respiratory protection.
• Open the latches on the maintenance door.
• Open the maintenance door of the device.
• Remove and discard the dust collection charge as described in Chapter 7.4.
• Remove the nut of the filter cartridge bracket using an offset ring SW19-size
spanner.
• Position the disposal bag under the filter cartridge before you remove the nut
fully.
• Lower the filter cartridge into the waste disposal bags and pack the filter
cartridge into the disposal bag.
KEMPER Filter-Master XL Operating Instructions - EN

Figure 6, filter cartridges bracket

- 71 –
Technical changes and errors excepted.