Descargar Imprimir esta página

Dometic TEC29LPG Instrucciones De Montaje página 27

Ocultar thumbs Ver también para TEC29LPG:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69
TEC29, TEC29LPG
10.3
Connecting 230 V
A
NOTICE!
• Connect a relay or a switch to the vehicle's electrical system so that
the generator is not damaged when the external mains is connected.
• Ensure that the electrical system is set up as follows:
– TN network:
The neutral conductor must be linked to the PE conductor on the
terminal via a jumper with a minimum diameter of 2.5 mm
protect against automatic shutdown, make sure that a safety
switch (FI switch, 30 mA) and an in all-pole overcurrent protec-
tion (e.g. circuit breaker, 13 A) are installed.
– IT network:
Ensure that an insulation monitor and an in all-pole overcurrent
protection (e.g. circuit breaker, 13 A) are installed.
• Connect the generator so that it takes priority over the power supply.
➤ Guide the 230 V connection cable through the cable passage in the housing and
connect it to the 230 V terminals (for TEC29: fig. e 7, page 9, for TEC29LPG:
fig. f 6, page 9).
➤ Connect the earth cable to the earth connection on (for TEC29: fig. e 6,
page 9, for TEC29LPG: fig. f 7, page 9).
10.4
Connecting the battery charger
➤ Connect the positive terminal of the battery with the 12 V connection of the bat-
tery charger using a cable with a cross-section of 2.5 mm² (for TEC29: fig. e 5,
page 9, for TEC29LPG: fig. f 8, page 9).
➤ If the battery to be charged is not also the starter battery, connect the negative
terminal of the battery to be charged to the generator's earth cable (fig. g 1,
page 10).
EN
Connecting the electrical power to the generator
2
. To
27

Publicidad

loading

Este manual también es adecuado para:

Tec29