DESCRIPTION
The 12 Volt Advanced Notification System includes a DC back-
up sump pump, an electronic controller with digital display, and
an auto-dialer. Optimal back-up power is supplied by a 12 volt
battery (not included). The system is designed for home sump
applications. When an electrical power outage occurs, the
electronic controller automatically switches the sump pump to
battery power. Power loss will initiate a phone call via the auto-
dialer to the phone number(s) entered by the homeowner. With
a 24-hour monitor and a predetermined full system check, the
system tells you it's status via a digital display and alerts you to
potential problems with an audible horn and phone call.
UNPACKING
Inspect this unit before it is used. Occasionally, products are
damaged during shipment. If the pump or components are
damaged, contact customer service at 1.877.9RIDGID.
SAFETY GUIDELINES
To help recognize this information, observe the following signal
words/hazard classifications.
This is the safety alert symbol. It is used to alert you to
potential bodily injury hazards. Obey all safety messages that
follow this symbol to avoid possible harm.
Danger indicates an imminently hazardous
situation which, if NOT avoided, WILL result
in death or serious injury.
Warning indicates a potentially hazardous
situation which, if NOT avoided, COULD
result in death or serious injury.
Caution indicates a potentially hazardous
situation which, if NOT avoided, MAY result
in minor or moderate injury.
Notice indicates important information, that if
NOT followed, MAY cause damage to equipment.
GENERAL SAFETY INFORMATION
This pump is NOT rated for use with flammable/
combustible liquids vapors or dusts.
Do NOT use to pump flammable/combustible liquids vapors
or dusts. Do NOT use in a flammable and/or explosive
atmosphere. Pump SHOULD be used to pump clear water
ONLY. Failure to follow these instructions WILL result in bodily
injury or death.
Electric shock hazard. Disconnect
power before servicing. Apply a fixed
lock or tag to prevent unexpected application of power.
Electric shock hazard. DO NOT walk
on wet floor until power is disconnected. Use a
licensed electrician to perform service in accordance with the National
Electrical Code and all local codes.
NEVER allow children to use pump.
Model RSM3300 - Operating Instructions and Parts Manual
effluent, salt water, brine, laundry discharge, or any other application
which MAY contain caustic chemicals and/or foreign materials. Pump
damage MAY occur if used in these applications and WILL void warranty.
SPECIFICATIONS
Power Supply Requirements ......120 V, 60 Hz
Motor ..........................................12 V DC Motor
Pump Dimensions ......................11 in. high x 8 3/4 in. base
CONSTRUCTION
Motor Housing ...........................
Impeller ......................................
Shaft ..........................................
Discharge ..................................
Float Switch ..............................
BATTERY INFORMATION
The system is designed to operate most efficiently with a
deep cycle, sealed lead (Pb) acid (SLA) battery. A deep cycle
marine battery can also be used. Sealed lead acid batteries cost
slightly more, but they can last longer than a wet cell battery and
are maintenance free. The oversize battery case (included) will
accomodate one 12 Volt battery up to a 27-frame size. Use a new
battery. Chart 1 illustrates the expected performance with various
battery combinations. Do not use batteries rated below 40 amp
hours. Be certain that the area around the battery is well ventilated.
Before servicing the battery, blow away gasses by waving a piece
of cardboard near the battery. An assistant should be present or
close enough to come to your aid in the event of an emergency.
Have a reliable source of fresh water and soap nearby in case
battery acid contacts clothing, skin or eyes. Wear eye and clothing
protection when working around lead acid batteries. Avoid touching
your eyes when working around lead acid batteries.
connections MUST be performed in a well ventilated area.
CALIFORNIA PROPOSITION 65
State of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
copious amounts of clean, tepid water for at least 30 minutes. Seek
medical attention.
Ridge Tool Company
Battery acid is corrosive. Avoid spilling on skin or
clothing. Eye protection MUST be worn when
handling the battery.
A check valve MUST be used on the primary
and back-up sump discharge.
A ground fault circuit interrupter is required.
This pump MUST only be used to pump clear
water. This pump is NOT designed to handle
Thermoplastic
Thermoplastic
Stainless Steel
1-1/2 in. NPT
Dual Reed
Explosion hazard. Smoking and open flames
prohibited. Battery recharging and
This product or its power cord MAY contain
chemicals, including lead, known to the
Chemical hazard. If battery acid contacts
your eyes, immediately flush eyes with
3